9.3 Other technical data
TOTAL POWER:
Gas original: G20 (2H) 20 mbar 9 kW
Gas replace-
ment:
G30 (3+) 28-30 mbar 654 g/h
G31 (3+) 37 mbar 643 g/h
Electric supply: 220-240 V ~ 50/60 Hz
Appliance cate-
gory:
II2H3+
Gas connection: G 1/2"
Appliance class: 3
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
Triple Crown 4,0 1,4 146
Semi-rapid 2,0 0,45 96
Auxiliary 1,0 0,33 70
9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Triple Crown 4,0 1,4 98 291 286
Semi-rapid 2,0 0,45 71 145 143
Auxiliary 1,0 0,33 50 73 71
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification HG654421UM
Type of hob Built-in hob
Number of gas burners 4