4. Release the emergency emptying hose,
place it in the container and remove its cap
cover.
1
2
5. When the water stops flowing, unscrew the
filter cover by turning it anti-clockwise and
remove the filter. Use pliers if necessary.
Always keep a rag nearby to dry up any water
spillages when removing the cover. Clean the
filter under a tap to remove any traces of fluff.
6. Remove foreign bodies and fluff from the
filter seat and from the filter impeller.
7. Check carefully whether the pump impeller
rotates (rotation is not completely smooth). If
it doesn’t rotate, please contact the
Authorised Service Centre.
1
2
8. Put the cap back on the emergency
emptying hose and push back into position.
Use the guides to push the filter pump back
into place. Tighten the filter cover by turning
it clockwise.