TECHNICAL DATA
Hob dimensions
Width: 880 mm
Length: 510 mm
Hob recess dimensions
Width: 830 mm
Length: 480 mm
Heat input
Triple Crown burner: 3.8 kW
Semi-rapid burner: 1.9 kW
Auxiliary burner: 1.0 kW
TOTAL POWER: G20 (2H) 20 mbar = 10.5 kW
G30 (3+) 28-30 mbar = 763 g/h
G31 (3+) 37 mbar = 750 g/h
Electric supply: 230 V ~ 50 Hz
3 core flexible cable with non rewireable plug
fitted with a 3 amp cartridge fuse
Category: II2H3+
Gas connection: G 1/2"
Gas supply: G20 (2H) 20 mbar
Appliance class: 3
By-pass diameters
Burner Ø By-pass in 1/100 mm
Auxiliary 28
Semi-rapid 32
Triple Crown 56
Gas burners
BURNER
NORMAL
POWER
REDUCED
POWER
NORMAL POWER
NATURAL GAS
G20 (2H) 20 mbar
LPG (Butane/Propane)
G30/G31 (3+) 28-30/37 mbar
kW kW
inj. 1/100
mm
m³/h
inj. 1/100
mm
G30
28-30
mbar
G31
37 mbar
g/h g/h
Auxiliary 1.0 0.33 70 0.095 50 73 71
Semi-rap-
id
1.9 0.45 96 0.181 71 138 136
Technical data 19