Aeg HE604000XB Manuel d'utilisateur Page 14

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 44
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 13
Install correctly to give shock protection.
Loose and incorrect plug and socket connections can make the terminal become too hot.
A qualified electrician must install the connections in the clamps correctly.
The appliance must have the electrical installation which lets you disconnect the appliance
from the mains at all poles with a contact opening width of minimum 3 mm.
You must have correct devices to isolate: line protecting cut-outs, fuses (screw type fuses
removed from the holder), earth leakage trips and contactors.
Assembly
min.
50mm
min.
50mm
min.
500mm
600 mm
560
+1
mm
R5
490
+1
mm
min.
28 mm
14 Installation instructions
Vue de la page 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 43 44

Commentaires sur ces manuels

Pas de commentaire