4.3 Adjustment of minimum
level
WARNING!
Information for authorised
installer only.
Switch off the hob before
the adjustment.
To adjust the minimum level of the
burners:
1. Touch for 3 seconds.
2. Within 7 seconds, touch for 3
seconds.
3. Touch 4 times.
The display shows G2 mode.
4. Touch
.
To enter the mode.
5. Wait 5 seconds, after selecting the
mode.
The burner shows minimum level and the
control bar shows .
6. Touch
or .
To increase or decrease the value and
adjust the minimum level.
7. Wait 5 seconds.
To send the selected value to power
board.
8. Check it the minimum level is correct
and touch .
To confirm the minimum level.
If the minimum level is
incorrect, repeat the steps 6
and 7.
9. Touch to select the next burner
and repeat the steps 5-8.
Touch to exit the mode.
WARNING!
Make sure the flame does
not go out when you move
quickly from the maximum
to the minimum heat setting
position.
WARNING!
Do not set the G3 and G4
modes. It is for authorised
installer only.
4.4 Electrical connection
The appliance is supplied with a
standard 7.5 Amp service cord
terminated by a 3-pin plug for
connection to a standard household
socket. The electrical supply is required
to power the electronic ignition system.
To disconnect the electrical
power supply, it is necessary
to service. After installation,
the power point should be
accessible according to local
wiring regulations.
Make sure that the rated voltage and
type of power on the rating plate
agree with the voltage and the power
of the local power supply.
This appliance is supplied with a
mains cable and a plug.
Always use a correctly installed
shockproof socket.
Make sure that there is an access to
the mains plug after the installation.
Do not pull the mains cable to
disconnect the appliance. Always pull
the mains plug.
There is a risk of fire when the
appliance is in connection with an
extension cable, an adapter or a
multiple connection. Make sure that
the ground connection agrees with
the standards and regulations.
Do not let the power cable to heat up
to a temperature higher than 90° C.
Make sure that you connect
the blue neutral cable to the
terminal with a letter "N" on
it. Connect the brown (or
black) phase cable to the
terminal which has a letter
"L". Keep the phase cable
connected at all times.
To prevent contact between
the cable and the appliance
below the hob use the
clamps which are on the side
of the cabinet.