8. INSTALLATION
WARNING!
Refer to the Safety chapters.
WARNING!
The following instructions about
installation, connection and
maintenance must be carried out
by qualified personnel in compli-
ance with standards and local
regulations in force.
8.1 Important safety
requirements
This hob must be installed in accordance
with the Gas Safety (Installation and Use)
Regulations (Current Edition) and the IEE
Wiring Regulations (Current Edition).
For appliances installed in the Republic
of Ireland please refer to NSAI- Domes-
tic Gas Installation I.S. 813 Current Edi-
tions and the ETCI Rules for Electrical In-
stallations.
Provision for ventilation
Detailed recommendations are con-
tained in the following British Standards
Codes Of Practice: B.S. 6172/ B.S. 5440,
Par. 2 and B.S. 6891 Current Editions.
The hob should not be installed in a bed
sitting room with a volume of less than
20 m³. If it is installed in a room of vol-
ume less than 5 m³ an air vent of effec-
tive area of 100 cm² is required. If it is in-
stalled in a room of volume between 5
m³ and 10 m³ an air vent of effective area
of 50 cm² is required, while if the volume
exceeds 11 m³ no air vent is required.
However, if the room has a door which
opens directly to the outside no air vent
is required even if the volume is be-
tween 5 m³ and 11 m³.
If there are other fuel burning appliances
in the same room, B.S. 5440 Part 2 Cur-
rent Edition, should be consulted to de-
termine the requisite air vent require-
ments.
For appliances installed in the Republic
of Ireland please refer to the NSAI- Do-
mestic Gas Installation I.S. 813 Current
Editions Table Four.