The replacement of the electrical
cable must be done by a qualified
electrician or competent person,
according to the current regula-
tions.
REPLACEMENT OF THE
CONNECTION CABLE
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to
the voltage and the working temperature.
The yellow/green earth wire must be ap-
proximately 2 cm longer than the brown
(or black) phase wire.
BUILDING IN
min. 45 mm
min. 650 mm
560 mm
min. 450 mm
40 mm
490 mm
+2
0
+2
0
min. 600 mm
A
A)
supplied brackets
POSSIBILITIES FOR INSERTION
Kitchen unit with door
The panel installed below the hob must
be easy to remove and let an easy access
in case a technical assistance intervention
is necessary.
min 20 mm
(max 150 mm)
40 mm
60 mm
a
b
a)
Removable panel
b)
Space for connections
Kitchen unit with oven
The hob recess dimensions must obey the
indication and the kitchen unit must be
equipped with vents to let a continuous
supply of air. The electrical connection of
the hob and the oven must be installed
separately for safety reasons and to let
easy remove oven from the unit.
50 cm
2
360 cm
2
180 cm
2
120 cm
2
TECHNICAL DATA
Hob dimensions
Width: 576 mm
Length: 516 mm
16