The connection should be suitable for
connecting to R 1/2 (1/2 BSP male
thread).
When the final connection has been
made, it is essential that a thorough leak
test is carried out on the hob and instal-
lation.
Make sure that the main connection
pipe does not exert any strain on the
hob.
If you use flexible metal pipes make sure
that they agree to ISO 10380 and ISO
10807 standards. Be careful they do not
come in touch with mobile parts or they
are not squeezed. Also be careful when
the hob is put together with an oven.
It is important to install the elbow
correctly, with the shoulder on
the end of the thread, fitted to
the hob connecting pipe.
Failure to ensure the correct as-
sembly will cause leakage of gas.
Make sure that the gas supply
pressure of the appliance obeys
the recommended values.
Rigid connection:
Carry out connection by using metal rig-
id pipes (copper with mechanical end).
8.3 Injectors replacement
1.
Remove the pan supports.
2.
Remove the caps and crowns of the
burner.
3.
With a socket spanner 7 remove the
injectors and replace them with the
ones which are necessary for the
type of gas you use (see table in
"Technical Information" chapter).
4.
Assemble the parts, follow the same
procedure backwards.
5.
Replace the rating plate (it is near
the gas supply pipe) with the one for
the new type of gas supply. You can
find this plate in the package sup-
plied with the appliance.
If the supply gas pressure is changeable
or different from the necessary pressure,
you must fit an applicable pressure ad-
juster on the gas supply pipe.
8.4 Adjustment of minimum
level
To adjust the minimum level of the burn-
ers:
1.
Light the burner.
2.
Turn the knob on the minimum posi-
tion.
3.
Remove the knob.
4.
With a thin screwdriver, adjust the
by-pass screw position.
A
A)
The by-pass screw
If you change from natural gas G20 20
mbar to liquid gas, fully tighten the
adjustment screw in.
If you change from liquid gas to natu-
ral gas G20 20 mbar, undo the by-pass
screw approximately 1/4 of a turn.
WARNING!
Make sure the flame does not go
out when you quickly turn the
knob from the maximum position
to the minimum position.
8.5 Electrical connection
Do not pull the mains cable to discon-
nect the appliance. Always pull the
mains plug.
The appliance must not be connected
with an extension cable, an adapter or
a multiple socket. There is a risk of fire.
Do not let the power cable to heat up
to a temperature of more than 90° C.
The cable should be guided by means
of clamps fixed to the side of the cabi-
net, in order to avoid any contact with
the equipment beneath the cooktop.
Make sure that there is access to the
mains plug after the installation.